Journal of the European Optical Society - Rapid publications, Vol 8 (2013)

Spherical refractive correction with an electro-optical liquid lens in a double-pass system

F. Sanàbria, F. Díaz-Doutón, M. Aldaba, J. Pujol

Abstract


In this study we show a novel double-pass configuration to correct the spherical refractive error by means of an electro-optical liquid lens.The proposed method enables spherical correction in the -12 D to +7 D range without movable parts using an electro-optical liquid lens.We have measured the optical performance of the spherical corrector in terms of power, pupil size and optical quality verifying that it fitsthe requirements to be applied to a double-pass system. We have also evaluated the performance of the proposed method in patients bycomparison with a conventional double-pass system using a Badal optometer.

© The Authors. All rights reserved. [DOI: 10.2971/jeos.2013.13062]

Full Text: PDF

Citation Details


Cite this article

References


J. Santamaría, P. Artal, and J. Bescós, ”Determination of the pointspread function of human eyes using a hybrid optical-digital method,” J. Opt. Soc. Am. A 4, 1109–1114 (1987).

A. Guirao, C. González, M. Redondo, E. Geraghty, S. Norrby, and P. Artal, ”Average optical performance of the human eye as a function of age in a normal population,” Invest. Ophthalmol. Vis. Sci. 40, 203–213 (1999).

M. Vilaseca, A. Padilla, J. Pujol, J. C. Ondategui, P. Artal and J. L. Güell, ”Optical quality one month after verisyse and Veriflex phakic IOL implantation and Zeiss MEL 80 LASIK for myopia from 5.00 to 16.50 diopters,” J. Refract. Surg. 25, 689–698 (2009).

J. F. Castejón-Mochón, N. López-Gil, A. Benito, and P. Artal, ”Ocular wave-front aberration statistics in a normal young population,” Vision Res. 42, 1611–1617 (2002).

R. Martínez-Cuenca, V. Durán, V. Climent, E. Tajahuerce, S. Bará , J. Ares , J. Arines , M. Martínez-Corral, and J. Lancis, ”Reconfigurable Shack-Hartmann sensor without moving elements,” Opt. Lett. 35, 1338–1340 (2010) .

S. Murali , P. Meemon, K. S. Lee, W. P. Kuhn, K. P. Thompson, and J. P. Rolland, ”Assessment of a liquid lens enabled in vivo optical coherence microscope,” Appl. Optics 49, 145–156 (2010).

J. L. Güell, J. Pujol, M. Arjona, F. Diaz Douton, and P. Artal, ”Optical Quality Analysis System: Instrument for objective clinical evaluation of ocular optical quality,” J. Cataract Refract. Surg. 30, 1598– 1599 (2004).

P. Artal, I. Iglesias, N. López-Gil, and D. G. Green, ”Double-pass measurements of the retinal-image quality with unequal entrance and exit pupil sizes and the reversibility of the eye’s optical system,” J. Opt. Soc. Am. A 12, 2358–2366 (1995).

P. Artal, and R. Navarro, ”Monochromatic modulation transfer function of the human eye for different pupil diameters: an analytical expression,” J. Opt. Soc. Am. A 11, 246–249 (1994).

J. A. Martínez-Roda, M. Vilaseca, J. C. Ondategui, A. Giner, F. J. Burgos, G. Cardona, and J. Pujol, ”Optical quality and intraocular scattering in a healthy young population,” Clin. Exp. Optom. 94, 223– 229 (2011).

P. Artal, A. Benito, G. M. Pérez, E. Alcón , A. De Casas, J. Pujol, and J. M. Marín, ”An objective scatter index based on double-pass retinal images of a point source to classify cataracts,” PLoS One 6, e16823 (2011).