Journal of the European Optical Society - Rapid publications, Vol 9 (2014)

The narrow band AOTF based hyperspectral microscopic imaging on the rat skin stratum configuration

C. Zhang, H. Wang, J. Huang, Q. Gao

Abstract


A noncollinear acousto-optic tunable filter (AOTF) was designed with a comprehensive treatment of the properties of TeO2 as an acoustooptic (A-O) material. The results of optical testing validated that it predicted the performance of the designed AOTF. The bandwidth of the AOTF was very narrow in the visible light range. The high spectral resolution of AOTF was useful in practical applications to the hyperspectral imaging. The experimentally observed spectral pattern of the diffracted light was nearly the same as the theoretical result. The measured tuning relationship between the diffracted central optical wavelength and acoustic frequency was in accordance with the theoretical prediction. It demonstrates the accuracy of our design theory. Furthermore, by selecting the AOTF as the spectroscopic element, a hyperspectral microscopic imaging system was designed. The hyperspectral microscopic images of the rat skin tissue under the different optical center wavelength were acquired. The experimental results indicated that the imaging performance was satisfactory. The stratums of the rat skin can be clearly distinguished. The inner details of the epidermis and the corium can be shown on the hyperspectral microscopic images. Some differences also can be found by the comparison of the hyperspectal images under the different optical wavelengths. The study indicated the applicability and the advantage of our system on biomedicine area.

© The Authors. All rights reserved. [DOI: 10.2971/jeos.2014.14034]

Full Text: PDF

Citation Details


Cite this article

References


N. Gupta, R. Dahmani, and S. Choy, ”Acousto-optic tunable filter based visible-to near-infrared spectropolarimetric imager,” Opt. Eng. 41, 1033–1038 (2002).

V. B. Voloshinov, K. B. Yushkov, and B. B J. Linde, ”Improvement in performance of a TeO2 acousto-optic imaging spectrometer,” J. Opt. A 9, 341–347 (2007).

Y. Yuan, J. Y. Hwang, M. Krishnamoorthy, K. Ye, Y. Zhang, J. Ning, R. C. Wang, et. al. ”High-throughput acousto-optic-tunablefilter- based time-resolved fluorescence spectrometer for optical biopsy,” Opt. Lett. 34, 1132–1134 (2009).

S. Y. Ryu, J. W. You, Y. Kwak, and S. Kim, ”Design of a prism to compensate the angular shift error of the acousto-optic tunable filter,” Opt. Express 16, 17138–17147 (2008).

J. W. You, J. Ahn, S. Kim, and D. Kim, ”Efficient double-filtering with a single acoustooptic tunable filter,” Opt. Express 16, 21505–21511 (2008).

K. B. Yushkov, S. Dupont, J. C. Kastelik and V. B. Voloshinov, ”Polarization-independent imaging with an acousto-optic tandem system,” Opt. Lett. 35, 1416–1418 (2010).

I. C. Chang, ”Noncollinear acousto-optic filter with large angular aperture,” Appl. Phys. Lett. 25, 370–372 (1974).

P. A. Gass, and J. R. Sambles, ”Accurate design of noncollinear acousto-optic tunable filter,” Opt. Lett. 16, 429-431 (1991).

N. Uchida, ”Optical properties of single-crystal paratellurite (TeO2),” Phys. Rev. B 4, 3736–3745 (1971).

C. Zhang, Z .Zhang, Y. Yang, and H. Wang, ”The design and analysis of a noncollinear acousto-optic tunable filter,” Opt. Lett. 32, 2417–2419 (2007).

C. Zhang, Z. Zhang, H. Wang, and Y. Yang, ”Analysis of the optimum optical incident angle for an imaging acousto-optic tunable filter,” Opt. Express 15, 11883–11888 (2007).

D. R. Suhre, and J. G. Throdore, ”White-light imaging by use of a multiple passband acousto-optic tunable filter,” Appl. Opt. 35, 4494–4501 (1996).

N. Gupta, and V. B. Voloshinov, ”Development and characterization of two transducer imaging acousto-optic tunable filters with extended tuning range,” Appl. Opt. 46, 1081–1088 (2007).

http://www.auniontech.com/p/ao_modulator_aotf/AO_Tunable_ Filter.html

http://www.brimrose.com/cn/products/acousto_optics.html